PS 6010A | ||||
Item | Technique Parameter | |||
Power Stability Range | Input 175V-250V,full-load output change ±1%Input 160V-280V,full-load output change ±2% | |||
Load Characteristic | Difference between no-load and full-load ≤2% | |||
Short-circuit Protection | Load short-circuited,input current is 2.5 times heavier than full-load current Output Voltage is 0,cut off the power in 1 hour, transformers will be OK | |||
Operating Environment | -40℃ ~ +40℃ | |||
Insulation Characteristic | 1500V,There is no breakdown in 1 minute,1500V | |||
Output Voltage | ~AC60V±3V(50Hz) | |||
Output Current | 2.2A、3.2A、4.2A、6A、10A、15A(Choose any one) | |||
KA6000B | ||||
Item | Unit | Parameter | ||
Input Voltage Range | V | 180~240 | ||
Power Frequency | Hz | 50 | ||
Output Voltage | V | 60±1(Input 220V) | 60±4(Input 180-240V) | |
Rated Output Current | A | 1-15 Choose any one | ||
Auto Recovery Time | S | About 60 | ||
Overload Protection Current | A | Rated current +1 | ||
Inserter Frequency | MHz | 5-860 | ||
Insertion Loss | dB | 1.5±0.5 | ||
Return Loss | dB | 5-550MHz≥16 | 550-860MHz≥14 | |
Maximum Operating Environment Temperature | ℃ | 50 | ||
KA6000backup | ||||
Item | Unit | Parameter | ||
Input Voltage Range | V | 180~250 | ||
Power Frequency | Hz | 50 | ||
Output Voltage | V | 60±3 | ||
Rated Output Current | A | 1-15Choose any one | ||
Auto Switch Time | S | Master machine:1S | Slave machine:3S | |
Overload Protection Current | A | 1.5 times than rated voltage | ||
Inserter Frequency | MHz | 5-862 | ||
Insertion Loss | dB | 1.5±0.5 | ||
Return Loss | dB | 5-550MHz≥16 | 550-860MHz≥14 | |
Maximum Operating Environment Temperature | ℃ | 50 | ||
Dimension | mm | 310mm×215mm×210mm | ||